SZPhoton Universal Light Cables accept different stainless steel adapters, allowing versatile use of the light sources for different endoscopes, such as Richard Wolf, Karl Storz, Olympus, Stryker and other adapters on request. They are compatible with different endoscopes, microscopes, and medical instruments.

  • High Temperature Resistance and High Pressure
  • High White Light Transmission with low color shift
  • Stainless Steel Coil plus Nylon Mesh Grid for internal protection
  • Medical Grade silicone for External protection
  • Suitable for fully Autoclave, 134℃, 3bar, 10mins
  • Versatility color of sheathing available
LG CABLE CUSTOMIZATION FORM

wdt_ID Attributes values
1 Fiber Type Bonded (Glued) Fiber / Fused Fiber
2 Active diameter φ1.8mm /φ2.5mm /φ3.5mm /φ4.8mm or on request
3 Length of cable 1.8m / 2.5m / 3.0m / 3.5m or upon request
4 Adapter Compatible Carl Storz / Olympus / Wolf/ Stryker/ ACMI / or other
5 Available Light Source LED, Halogen, Xenon
6 Sterilization method Autoclaving 134℃, 10 min , >100 cycles
7 Minimum Bending Radius 50mm
8 Sheathing Internal–Stainless Armor + Mesh Grid; External Silicone Color- grey, blue, white

The cables can be manufactured with different end-surface treatment of fiber.

1/Bonded or Glued

Bonded fiber cables are filled out with high temperature adhesives in between the spaces, generally used with Halogen light sources.

2/Fused (on the light source end)

Fused fiber cables are made by high pressure and heat on the light source end. In comparison with bonded fiber cables, they have the following benefits.

  • Provide 20%~30% more light transmission on the light source end
  • Increase the ability to withstand high temperature and light intensities
  • Used with high intensity Xenon light sources

3/Extremely fused (on both end)

Extremely hot fused fiber cables are made by high pressure and heat on both end. In comparison with the other two, they have the following benefits.

  • Provide 20%~30% more light transmission on both end
  • Increase the ability to withstand high temperature and light intensities
  • Used with high intensity Xenon light sources

Fused fiber

Bonded (glue) fiber

Lighting Cables for Matching Stryker Endocope

Lighting Cables for Matching Carl Storz Endoscope

Lighting Cables for Matching Olympus Endoscope

Lighting Cables for Matching Wolf Endoscope

Fiber Light Cables for Surgical (operation) Microscope

Light cones

Fiber light bundle for flexible fiber-optic endoscope