Specifications
-
Single Fiber diameter
Smaller fiber size means higher resolution. (2.5um = 218lp/mm , 6um = 114um )
- 2.5um
- 3um
- 4um
- 6um
-
Maximum Size (Diagonal)
Production cost will increase sharply once diagonal surpass 130mm. If you need a bigger size, please contact us.
- Max. size Φ200mm
-
Thickness
With a larger size of FOP, the minimum thickness required will also go up in order to maintain the structure. Usually thickness will go around 1mm - 3mm.
- Minimum 0.2mm
-
EMA Absorber
EMA are special fibers insert in-between the standard fibers. They are using to absorb stray light between fibers. But at a cost of lowering the overall transmission.
- Interstitial
- Without
-
Numerical Aperture
Numerical Aperture are decided by the material using to produce the FOP.
- NA = 1.0
-
Wavelength
sFOP are produced from multi-component glass. Which has the highest transmission in VIS to NIR range. For UV application, other material will be used.
- 400 - 1350nm
-
Transmission
Tested a sFOP of 5mm thickness, with EMA absorber, collimated light.